Digital Phoropter and Refractor EDR-H
A computerized refracting system designed to streamline subjective refraction and improve exam-lane efficiency.
Brand: Ezer Model: EDR-H Condition: New
Key Features
Wide sphere, cylinder, axis and prism measurement ranges
Automated cross-cylinder functions
Dedicated controller with integrated printer
Compatible with connected lensmeter, autorefractor and digital chart workflows
Contact Equipment Express for current pricing, availability, configuration details, and compatible accessories.
Dual Cross Cylinder Lens A new and improved method to refine the cylinder axis and power using theDual Cross Cylinder Lens. This allows the patient to see a split/dual image of the test object so they can easily discern which image is more visually appealing. This feature reduces patient confusion and speeds up the refraction process.Cross cylinderexamination is more precise and effective for astigmatism exams as the doctor can adjust the axis incremental change for higher cylindrical powers. The spherical equivalent can also be adjusted automatically.
Ergonomic Design Measuring a patient’s refractive index and eyeglass prescription is painless with the EDR-H. TheEDR-His designed to perform all kinds of tests for astigmatism, spherical refinement, binocular vision, and more. The carefully crafted lenses within this digital refractor provide a wide dioptric range(-29D to +26.75D)providing accurate measurements regardless of myopic severity. Due to the wide viewing angle of 40 degrees, the test results can be accurately secured.
Advanced Engineering The step motors operate at fast speeds, ensuring that the lenses are placed properly for the patient, reducing patient confusion and significantly speeding up the exam process. Thanks to Ezer’s engineering expertise, all of the adjustments that need to be done by the refractor during and between tests are handled by the headset’s quiet internal mechanisms.
Visual Charts and Tests TheEDR-Hoffers worldwide standardized charting. With a built-in System Program, Custom Programs and Unit Test Functions, the possibilities are endless. Practitioners can completely control the exam according to their own professional preference.
Near Eye Chart The Vision Test function makes it is easy to help patients understand the differences between various refractive errors and diseases. The near visual acuity test can be done with the near eye chart and auxiliary eye chart. These eye charts can be selected depending on user’s taste and the testing goals.
Closed Optical System TheEDR-Hhas been designed with an enclosed optical system. This minimizes the chances of a patient's ocular fluids contaminating the internal lenses.
Forehead Sensor The Forehead location detector is equipped with alert features to indicate each patient's optimum face location for testing. This system can also check to ensure that patients are maintaining correct postural positioning during each test.
Large Screen and Convenient Touch Screen Display Most of the interface is controlled by the touchscreen, with only a few physical buttons on the base of the equipment to control the most essential features. As the diagnoses progresses, figures are expressed on an 10.4 inch wide screen with intuitive interface with various colors. The display setup is easy to understand, making the practitioner aware of the testing content. By adopting a touch-screen interface, optometrists can use the most advanced technology, even if they are not fully familiar with this progressive technology.
Provide Tilting & Swivel Monitor Regardless of the position of the patient or the optometrist, the screen can be rotated to any angle or direction.
A large central dial allows users to change measurement values with a pleasing tactile sensation reminiscent of manual instruments, enhancing the user experience. The click function provides lens conversions and program executions in a much faster and convenient manner. The new and improved key design is arranged by function and has good touch sensitivity and improved durability.
Built In Printer All exam data is automatically stored on the control box and can be quickly pulled up by the user at any time. The control box also has a built-in printer to easily produce a hard copy of test results on-demand. Furthermore, the control box comes loaded with several easily digestible patient education slides — just tilt and swivel the screen towards the patient to get them engaged in their eye care.
Compatible Connection with Various Systems TheEDR-Hcan connect to several other digital ophthalmic instruments by Ezer to serve as the hub of the digitally-enabled exam room. Data can be entered or transferred directly from compatible devices, and the control box can operate many of the different functions of each device.
Wireless Networking (optional) EDR-BH can be connected to ERK-BH, EDC-BH and ELM-BH viaWIFI.
DIGITAL CLINIC
What is an EMR? Electronic Medical Records, commonly abbreviated as “EMR”, are a technological tool used widely in modern medical practices. EMR systems were designed to replace outdated paper charting methods and streamline the collection and tracking of patient data over time. EMR platforms integrate the various components of a doctor’s office visit, including intake demographics and medical history, prescription information, laboratory data, practice management software, exam notes, and more. Overall, EMR systems are used to promote economic efficiency and improved patient care through a seamless coordination of data collection and storage. EMR platforms also increase patient transparency through use of portals where patients can view important results and communicate with Doctor’s in a secure manner.
In the Ophthalmic industry,EMRare becoming more important and popular than ever. The ability to save critical lab data relating to prescriptions and diagnoses while maintaining quick access to that information is key in decreasing chair time and improving patient outcomes and satisfaction.
With theEzer Digital Practice, information sharing is easier than ever! TheELM-BH Lensometer, ERK-H/BH Autorefractor, EDR-H Phoropter, and EDC-BH Visual Acuity Chartall interact via Wifi to streamline communication between your pretest and exam rooms.
We know it can be scary to introduce a new technology to your practice, but with theEzer Digital Practiceequipment and US Ophthalmic’s superior tech support, your practice will save time and money with a seamless EMR integration.
Our EMR Partners
Easy Maintenance and Upgrade The forehead pedestal, facial contact piece, and eyepiece protective lens are designed to be detachable for easy removal and cleaning. This allows practitioners to maintain a hygienic test environment. Additional, the system software can be upgraded easily through the USB interface.
EDR-Hprovides ophthalmic practices with a unified experience and a fluent data platform. This instrument will provide a new level of synergy to your practice, benefiting patients, clinicians, and technicians alike.
EDR-H Video
Digital Practic
Sphere Power(SPH)
Measurement Range
-29.00 ~ +26.75D(general) -19.00 ~ +16.75D(cross cylinder or prism)