Ophthalmic A-Scan Biometer and Pachymeter EUS-1800 AP
Price shown at checkout. Review your total before payment.
Price shown at checkout. Review your total before payment.
A combined ultrasound biometer and pachymeter for axial-length, IOL and corneal-thickness measurements.
Brand: Ezer
Model: EUS-1800 AP
Condition: New
Contact Equipment Express for current pricing, availability, configuration details, and compatible accessories.
![]() |
Dual Scanning Probes The Ezer EUS-1800 A/P offers a 10MHz A-Scan Probe that allows for precise and accurate axial length measurements each and every time, while the 20MHz Pachymetry probe helps practitioners determine corneal thickness. |
|
![]() |
Several A-Scan Measuring Modes Contact and immersion measuring allow for automatic readings in four different modes: Normal, Cataract, Aphakic and Special. Manual measuring is also available. |
|
![]() |
Automatic A-Scan Readings The EUS-1800 A/P automatically takes eight readings for one group. Users can manually adjust reading results at any time during the automatic measuring. |
|
![]() |
IOL Calculation IOL calculation is simple and reliable with the EUS-1800 A/P. Select from six different formulae: SRK-II, SRK-T, BINKHOST-II, HOLLADAY, HOFFER-Q, and HAIGIS. You can even compare results of different formulae. |
|
![]() |
Accurate Corneal Thickness The EUS-1800 A/P takes automatic readings for corneal thickness. Select from multiple or single point readings. |
|
![]() |
IOP Parameters Standard CCT and IOL coefficient provide an excellent reference in glaucoma care and tonometry measurements. Corneal thickness distribution map allows for even more useful detail. |
|
![]() |
User-Defined Interface Complete control is at your fingertips with the EUS-1800 A/P. This unit allows you to define acoustic velocity, IOP parameters, printing options and so much more. |
|
![]() |
Standard Deviation The EUS-1800 A/P provides S.D. (Standard Deviation) to assist you in evaluating reading reliability. |
|
![]() |
Color LCD Touch Screen Biometry has never been easier thanks to the smart, menu-guided color touch screen users will enjoy when selecting the EUS-1800 A/P. |
|
![]() |
Built-in Printer For added efficiency, this compact unit even features a built-in thermal printer that offers user-defined printing options. |
|
![]() |
Data Management With the EUS-1800 A/P, you can store as many as 180 patient records for convenient archiving. Alternately, you can connect the system to a PC and automatically store as much data as you need. |
|
| A-Scan | ||||
| Probe | 10MHz with Fixation red Light | |||
| Total Gain | ≥ 100dB | |||
| Biometry Accuracy | ≤ ± 0.002in / 0.05 mm | |||
| Resolution | 0.0004in / 0.01 mm | |||
| Measuring Range | 0.59 - 1.57in (15 - 40 mm) | |||
| Measuring Mode | Contact, Immersion Mode | |||
| Measuring Parameters | Anterior Chamber Depth, Lens Thickness, Vitreous Length and Axial Length | |||
| Different Measure Modes | Automatic (for Normal, Cataract, Aphakic and Special) | |||
| 8 Auto Measuring Readings | Manually adjust auto measuring readings during auto measuring | |||
| IOL Formula |
SRK/II, SRK-T, BINKHOST-II, HOLLADAY, HOFFER-Q, HAIGIS |
|||
| Pachymeter | ||||
| Probe Frequency | 15-20 MHz | |||
| Display Resolution | 1 µ | |||
| Biometry Accuracy | ≤ ± 5 µm | |||
| Measuring Scope | 230-1200 µm Multiple corneal maps with graphical display |
|||
| Accesories | ||||
| Probe | ||||
| 10MHz P Probe | ||||
| Footswitch | ||||
| Test Object | ||||
| PC Suite | ||||
| AC Adapter | ||||