{"title":"Non-Contact Tonometers","description":"\u003cdiv style=\"max-width: 1100px; margin: 0 auto;\"\u003e\n\n  \u003cp style=\"font-size: 17px; line-height: 1.7; margin-bottom: 20px;\"\u003e\n    Shop \u003cstrong\u003enon-contact tonometers\u003c\/strong\u003e for fast, comfortable intraocular pressure screening in ophthalmology, optometry, and eye-care practices. Equipment Express offers new and refurbished air-puff tonometers from leading ophthalmic equipment manufacturers.\n  \u003c\/p\u003e\n\n  \u003cdiv style=\"background: #f7f9fc; border: 1px solid #e2e8f0; border-radius: 8px; padding: 22px 26px; margin: 24px 0;\"\u003e\n    \u003ch2 style=\"font-size: 20px; margin: 0 0 12px;\"\u003e\n      Non-Contact Tonometry for Efficient Eye Exams\n    \u003c\/h2\u003e\n\n    \u003cp style=\"line-height: 1.7; margin-bottom: 14px;\"\u003e\n      Non-contact tonometers use a controlled air pulse to measure intraocular pressure without requiring direct contact with the cornea. They are commonly used for glaucoma screening, routine eye examinations, pretesting, and high-volume clinical workflows.\n    \u003c\/p\u003e\n\n    \u003cul style=\"margin: 0; padding-left: 22px; line-height: 1.8;\"\u003e\n      \u003cli\u003eFast, non-contact intraocular pressure measurement\u003c\/li\u003e\n      \u003cli\u003eIdeal for ophthalmology and optometry practices\u003c\/li\u003e\n      \u003cli\u003eUseful for glaucoma screening and routine pretesting\u003c\/li\u003e\n      \u003cli\u003eAutomatic alignment and measurement options available\u003c\/li\u003e\n      \u003cli\u003eModels with pachymetry and advanced connectivity available\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size: 20px; margin-top: 28px; margin-bottom: 10px;\"\u003e\n    Find the Right Non-Contact Tonometer\n  \u003c\/h2\u003e\n\n  \u003cp style=\"line-height: 1.7; margin-bottom: 18px;\"\u003e\n    Whether you are outfitting a new pretest area, replacing an older air-puff tonometer, or upgrading your diagnostic workflow, our team can help identify the right system for your practice.\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 16px; line-height: 1.7; margin-bottom: 0;\"\u003e\n    \u003cstrong\u003eNeed help choosing a model?\u003c\/strong\u003e Request pricing and availability from Equipment Express and our team will help you compare compatible options.\n  \u003c\/p\u003e\n\n\u003c\/div\u003e","products":[{"product_id":"non-contact-tonometer-etn-1800-automatic-3d-tracking","title":"Non-Contact Tonometer ETN-1800 – Automatic 3D Tracking","description":"\u003ch2\u003eNon-Contact Tonometer ETN-1800 – Automatic 3D Tracking\u003c\/h2\u003e\n\u003cp\u003eAn automated air-puff tonometer designed to obtain fast, repeatable intraocular-pressure measurements with minimal operator input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Ezer\u003cbr\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e ETN-1800\u003cbr\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e New\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic 3D pupil tracking and alignment\u003c\/li\u003e\n\u003cli\u003eMotorized chinrest\u003c\/li\u003e\n\u003cli\u003eMeasurement range from 1 to 60 mmHg\u003c\/li\u003e\n\u003cli\u003eTouchscreen operation with integrated thermal printer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact Equipment Express for current pricing, availability, configuration details, and compatible accessories.\u003c\/p\u003e\n\u003cdiv class=\"col-p-80 col-pm-100\"\u003e\n\u003cdiv class=\"row row-0\"\u003e\n\u003cdiv class=\"col-p-60 col-pm-100\" align=\"center\"\u003e\u003cimg loading=\"lazy\" decoding=\"async\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0482\/5209\/2577\/files\/chinrest_db34586f-2153-4708-bde7-022a515c6bc7.gif?v=1620754173\u0026amp;width=800\" alt=\"tonometer etn-1800 ezer - usophthalmic\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-p-40 col-pm-100\"\u003e\u003cspan class=\"explain_table\"\u003eThe Tonometer\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eETN-1800\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eis designed with ease of use at the forefront. Once the patient’s head is placed in the attached motorized chin rest, the operator needs only to adjust the height of the chin rest and press a button on the built-in touchscreen display. The onboard software suite takes care of the rest and delivers results quickly and consistently.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-p-10 col-pm-100\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-p-80 col-pm-100\"\u003e\u003cspan class=\"explain_table\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eETN-1800\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003etonometer uses its advanced 3D tracking software to track the center of the patient’s pupil to minimize the influence of eye movements and make fine adjustments accordingly; no joystick required. This dramatically increases the speed of each exam, cutting time spent and improving patient throughput without additional extensive training. The built-in software of the\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eETN-1800\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003ealso allows it to use a quieter and softer air puff for applanation than other devices. This, combined with the rapid exam speed, maximizes patient comfort.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-p-10 col-pm-100\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-p-30 col-pm-100\" align=\"center\"\u003e\u003cimg loading=\"lazy\" decoding=\"async\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0482\/5209\/2577\/files\/etn1800mov1.gif?v=1620756685\u0026amp;width=800\" alt=\"tonometer ETN-1800 Ezer\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-p-30 col-pm-100\" align=\"center\"\u003e\u003cimg loading=\"lazy\" decoding=\"async\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0482\/5209\/2577\/files\/etn1800mov2.gif?v=1620756685\u0026amp;width=800\" alt=\"tonometer ETN-1800 Ezer\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-p-30 col-pm-100\" align=\"center\"\u003e\u003cimg loading=\"lazy\" decoding=\"async\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0482\/5209\/2577\/files\/etn1800mov3.gif?v=1620756685\u0026amp;width=800\" alt=\"tonometer ETN-1800 Ezer\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-p-10 col-pm-100\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-p-80 col-pm-100\"\u003e\u003cspan class=\"explain_table\"\u003eThe measurements of\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eIOP\u003c\/b\u003e, are critically important for the detection and diagnosis of glaucoma. The\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eETN-1800\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003etonometer measures ,calculates and displays the\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eIOP\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eautomatically.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-p-10 col-pm-100\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-p-80 col-pm-100\" align=\"center\"\u003e\u003cimg loading=\"lazy\" decoding=\"async\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0482\/5209\/2577\/files\/etn1800back04.jpg?v=1620759543\u0026amp;width=1200\" alt=\"tonometer ETN-1800 Ezer\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-p-10 col-pm-100\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-p-10 col-pm-100\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-p-80 col-pm-100\"\u003e\n\u003cdiv class=\"row row-0\"\u003e\n\u003cdiv class=\"col-p-60 col-pm-100\" align=\"center\"\u003e\u003cimg loading=\"lazy\" decoding=\"async\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0482\/5209\/2577\/files\/imgprint.jpg?v=1620760314\u0026amp;width=1200\" alt=\"tonometer etn-1800 ezer - usophthalmic\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-p-40 col-pm-100\"\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan class=\"explain_table\"\u003eThe large touch screen of the\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eETN-1800\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eallows for easy access to all operating procedures. In addition, this tonometer can be connected to patient records via\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eUSB\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eRS232\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eand has display, search, and input features that make it easy to look up and edit patient data on the fly. The built-in printer can be set to print results after every use automatically.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-p-40 col-pm-100\"\u003e\u003cspan class=\"explain_table\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-0\"\u003e\n\u003cb\u003eETN-1800 Video\u003c\/b\u003e\u003ciframe loading=\"lazy\" width=\"80%\" height=\"630\" src=\"https:\/\/www.youtube.com\/embed\/nARcPhMSCr4\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003cb\u003eEnglish Version\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row row-0\"\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003e1-60mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#b0afaf\" height=\"1\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003eMeasurement range setting\u003c\/td\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003eAuto\/ 30mmHg\/ 60 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#b0afaf\" height=\"1\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003eMeasurement principle\u003c\/td\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003eAir puff method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#b0afaf\" height=\"1\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003eDisplay units\u003c\/td\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003emmHg\/hpa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#b0afaf\" height=\"1\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003eWorking Distance\u003c\/td\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003e11 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#b0afaf\" height=\"1\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003eAlignment\u003c\/td\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003eFully automated 3D tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#b0afaf\" height=\"1\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003eChinrest\u003c\/td\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003eMotorized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#b0afaf\" height=\"1\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003ePrinter\u003c\/td\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003eThermal line printer with auto-cut function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#b0afaf\" height=\"1\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"30%\" height=\"20\" valign=\"middle\" class=\"td1_table\"\u003eInterface\u003c\/td\u003e\n\u003ctd width=\"70%\" height=\"20\" valign=\"middle\" class=\"td2_table\"\u003eUSB \/ RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#b0afaf\" height=\"1\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td1_table\"\u003ePower supply\u003c\/td\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td2_table\"\u003eAC 100V to 240V, 50\/60Hz, auto selected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#b0afaf\" height=\"1\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td1_table\"\u003eOperating Environment\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td2_table\"\u003eTemperature: 10°C to 35°C; Humidity: 30% to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#b0afaf\" height=\"1\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td1_table\"\u003eDimensions (WxDxH)\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td2_table\"\u003e12x20x20inch (282x500x500mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#b0afaf\" height=\"1\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd height=\"20\" valign=\"middle\" class=\"td1_table\"\u003eWeight\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td2_table\"\u003e38lbs (17 Kgs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Ezer","offers":[{"title":"Default Title","offer_id":55810491220290,"sku":"EE-OPH-ETN-1800","price":10200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0772\/0629\/0754\/files\/etn180000_1512x_92fcbe1c-306b-42cb-b01c-8e5993aa226c.webp?v=1787071123"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0772\/0629\/0754\/collections\/etn180000_1512x_92fcbe1c-306b-42cb-b01c-8e5993aa226c.webp?v=1787071244","url":"https:\/\/www.equipment.express\/en-ca\/collections\/non-contact-tonometers.oembed","provider":"Equipment Express LLC","version":"1.0","type":"link"}